SMDC – Multi-module
up to 300 kVA, hybrid cooling
Dieses Produkt ist in Ihrer Region nicht erhältlich!
Produktvarianten & Lagerbestand
Download
Artikel-Nr. | Lagerbestand | Produkt | IT load | Available space | Cooling / Condenser | Input power |
---|---|---|---|---|---|---|
41905003ZY | SMDC – Multi-module | up to 267 kW | up to 100 racks | In-row / outdoor | 380 - 415 VAC, 3Ph+N+PE 50/60Hz |
Technische Daten
The Smart Modular Data Centre (SMDC) is a scalable, pre-assembled, plug-and-play solution designed for edge computing and engineered for rapid deployment.
The multi-module SMDC ensures a capacity of up to 300 kVA. It consists of 42U racks, integrated intelligent power distribution, uninterruptible power supplies (UPS) and a flexible cooling system with a capacity of up to 25 kW per cooling unit.
It also includes a fire extinguishing system, air gap sealing and comprehensive software for infrastructure management.
This multi-module solution offers multiple configuration options for redundant power and cooling enabling seamless scalability and technology upgrades with little additional cost or disruption.
The multi-module SMDC ensures a capacity of up to 300 kVA. It consists of 42U racks, integrated intelligent power distribution, uninterruptible power supplies (UPS) and a flexible cooling system with a capacity of up to 25 kW per cooling unit.
It also includes a fire extinguishing system, air gap sealing and comprehensive software for infrastructure management.
This multi-module solution offers multiple configuration options for redundant power and cooling enabling seamless scalability and technology upgrades with little additional cost or disruption.
The multi-module SMDC supports edge computing, operating smart facilities with IoT devices, and running remote or branch offices. Advanced applications include technologies such as AI, AR, VR and automation systems that require flexible, scalable and energy-efficient real-time data processing. |
Notfall-Belüftung | Top of the rack and front door, extracting hot air from the rack in case of cooling failure |
---|---|
PDU | Intelligent power management |
USV-Kapazität | up to 300 kVA |
Verlängerung der Autonomiezeit der USV (optional) | 8 to 15 minutes |
Benutzeroberfläche | 10.4" touch screen and remote web interface |
Sensoren | Cooling system, UPS, power usage effectiveness (PUE), iPDU*, IT load, access control*, temperature, humidity and alarm status |
Alarm und Benachrichtigung | Sound and light alarm with SMS and email notification |
Zutrittskontrolle | Card or keypad |
Brandbekämpfung | FM200-J / NOVEC 1230 rack mounted (2U)* |
Fronttür | with 5 mm toughened double glass (does not apply to in-row cooler) |
---|---|
Rücktür | made of solid sheet steel |
Seitenwände | removable, with grounding bolt |
Dachplatte | Kabeleinführung möglich |
Bodenplatte | Kabeleinführung möglich |
Befestigungsprofil | 2 pairs of 19" vertical profiles (front / rear) |