FM – Low Fire Hazard – supported

Mid rise - travelling height maximum 150m

Drawing according to article number 185124 - Type 8696-F

04_Propagation 05_Spread- 06_Density 03_LS0H

Produktvarianten & Lagerbestand

Artikel-Nr. Lagerbestand ProduktKabelkonstruktionCu-Zahl [kg/km]Gewicht [kg/km]GTIN / EAN
185127
8622-F12 G 1.00 + 1 CX 75 Ω13948440393910077339
185124
8696-F12 G 1.00 + 1 x 4 x 0.34 mm² (STQ)14248640393910077360
191094
8872-F3 G 2.50 + 14 x 1.00 + 4 x 2 x 0.50 mm² (FTP)23281840393910069815

Technische Daten

Elevator suspension cable for indoor and panoramic elevators.
Ader black, white numbered, G = with green-yellow core(s)
Pair/quad various colours or black with white numbers
Coax schwarz
Betriebstemperatur -15 °C - +70 °C
Maximale freie Federung 80 m
Maximale Fahrhöhe 150 m
Maximale Laufgeschwindigkeit 6.3 m/s
Beschleunigung 1.2 m/s²
Empfohlener Schlaufendurchmesser according to table, tolerance -50/+100 mm
To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately
Nennspannung Uo/U according to table
Aderisolation low fire hazard
Kern Flexibel class 5
Unterstützende Elemente HTF = High tensile fibre
Mantelmaterial low fire hazard
Mantelfarbe schwarz
Norm für flexible Aufzugssteuerleitungen EN 50214

Dokumentation