FL –FRNC - without data elements
Low rise - travelling height maximum 80m
Drawing according to article number 191110 ; Type 8511-F
Produktvarianten & Lagerbestand
Download
| Artikel-Nr. | Lagerbestand | Produkt | Kabelkonstruktion | Cu-Zahl [kg/km] | Gewicht [kg/km] | GTIN / EAN |
|---|---|---|---|---|---|---|
| 191110 | 8511-F | 12 G 0.75 mm² | 87 | 259 | 40393910069716 | |
| 185125 | 8511-F | 18 G 0.75 mm² | 130 | 382 | 40393910077353 | |
| 191112 | 8511-F | 24 G 0.75 mm² | 173 | 511 | 40393910069693 |
Technische Daten
Elevator suspension cable for indoor and panoramic elevators.
| Pair/quad | various colours or black with white numbers |
|---|---|
| Ader | black, white numbered, G = with green-yellow core(s) |
| Coax | schwarz |
| Betriebstemperatur | -15 °C - +70 °C |
| Nennspannung Uo/U | according to table |
|---|
| To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately |
| Aderisolation | low fire hazard |
|---|---|
| Kern Flexibel | class 5 |
| Unterstützende Elemente | none |
| Mantelmaterial | low fire hazard |
| Mantelfarbe | schwarz |
| Norm für flexible Aufzugssteuerleitungen | EN 50214 |
|---|
| Maximale Fahrhöhe | 80 m |
|---|---|
| Maximale freie Federung | 45 m |
| Maximale Laufgeschwindigkeit | 4 m/s |
| Empfohlener Schlaufendurchmesser | according to table, tolerance -50/+100 mm |
| Beschleunigung | 0.8 m/s² |