FM – PVC – supported

Mid rise - travelling height maximum 150m

Drawing according to article number 177690 - Type 8666-F

04_Propagation 05_Spread- 06_Density- 03_LS0H-

Produktvarianten & Lagerbestand

Artikel-Nr. Lagerbestand ProduktLoop [mm]Suspension deviceKabelkonstruktionSupporting membersDatenelementeÄußere Abmessungen (HxBxT)Gewicht [kg/km]GTIN / EAN
165344
6599-F300LZ 100924 G 0.75 mm²HTFnone4.3 mm x 73.1 mm54840393910079883
156879
7770-F400LZ 100924 G 0.75 mm²ST Ø 2.5none4.3 mm x 73.2 mm58240393910080032
176877
6900-F400LZ 10066 G 1.50 + 6 x 1.00 + 1 x 4 x 0.50 mm² (STQ)HTF1 x 6347/3-F6.4 mm x 53.0 mm56740393910078459
166612
7500-F400LZ 100612 G 1.00 mm² + 1 CX 75 ΩHTF1 x HF-2122-F6.4 mm x 50.9 mm51640393910079852
177690
8666-F400LZ 100612 G 1.00 + 1 x 4 x 0.34 mm² (STQ)HTF1 x 8607-F6.4 mm x 50.9 mm52240393910078305
167018
8210-F450LZ 10062 x 1.50 + 8 x 2 x 0.50 mm² (FTP) + 1 CX 75 ΩHTF1 x HF-2122-F + 8 x 6651-F7.1 mm x 54.1 mm56540393910079838
168191
8210-F450LZ 10094 x 1.50 + 8 x 2 x 0.50 mm² (FTP) + 2 CX 75 ΩHTF2 x HF-2122-F + 8 x 6651-F7.0 mm x 64.3 mm64040393910079722
182058
8820-F500LZ 10094 x 1.50 + 8 x 2 x 0.50 mm² (FTP) + 2 CX 75 ΩST Ø 2.52 x HF-2122-F + 8 x 6651-F7.0 mm x 64.3 mm72340393910077773
168185
8507-F400LZ 100612 x 2 x 0.50 mm² (FTP)HTF12 x 6651-F5.6 mm x 54.1 mm44540393910079746
191093
8512-F400LZ 10093 G 2.50 + 14 x 1.00 + 4 x 2 x 0.50 mm² (FTP)ST Ø 2.54 x 6651-F5.7 mm x 79.0 mm80240393910069822
192453
8884-F400LZ 10068 x 0.75 mm² + 4 FO G50/125 µmST Ø 2.54 x GF-23144.3 mm x 40.8 mm30140393910067491

Technische Daten

Elevator suspension cable for indoor and panoramic elevators.
Ader black, white numbered, G = with green-yellow core(s)
Pair/quad various colours or black with white numbers
Coax grau
Betriebstemperatur -15 °C - +70 °C
Maximale freie Federung 80 m
Maximale Fahrhöhe 150 m
Maximale Laufgeschwindigkeit 3.0 m/s
Beschleunigung 1.2 m/s²
Empfohlener Schlaufendurchmesser according to table, tolerance -50/+100 mm
To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately
Nennspannung Uo/U according to table
Aderisolation PVC
Kern Flexibel class 5
Unterstützende Elemente HTF = High tensile fibre, ST = Steel, diameter in [mm]
Mantelmaterial PVC
Mantelfarbe grau
Norm für flexible Aufzugssteuerleitungen EN 50214

Dokumentation