FH Module Concept – Low Fire Hazard
High rise - travelling height maximum 400m
Drawing according to article number 191114 - Type 8859-F




Produktvarianten & Lagerbestand
Download
Artikel-Nr. | Lagerbestand | Produkt | Kabelkonstruktion | Gewicht [kg/km] | GTIN / EAN |
---|---|---|---|---|---|
191114 | 8859-F | 12 G 2.00 + 30 x 1.00 + 7 x 2 x 0.50 (FTP) + 3 x 4 x 0.50 mm² (STQ) | 1929 | 40393910069679 | |
191483 | 8866-F | 10 G 2.50 + 7 x 1.50 + 6 x 1.00 + 12 x 2 x 0.75 mm² (FTP) + 4 FO G50/125 µm | 2184 | 40393910069297 |
Technische Daten
Elevator suspension cable for indoor and panoramic elevators
Ader | black, white numbered, G = with green-yellow core(s) |
---|---|
Pair/quad | various colours or black with white numbers, |
Glasfasern | orange 50 Μm, grey 62.5 Μm |
Bündeln | with black sheath |
Coax | schwarz |
Betriebstemperatur | -15 °C - +70 °C |
Maximale freie Federung | 220 m |
---|---|
Maximale Fahrhöhe | 400 m |
Maximale Laufgeschwindigkeit | 12 m/s |
Beschleunigung | 1.2 m/s² |
Empfohlener Schlaufendurchmesser | approx. 650 mm, tolerance -50/+150 mm |
To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately. |
Nennspannung Uo/U | according to table |
---|
Aderisolation | low fire hazard |
---|---|
Kern Flexibel | class 5 |
Unterstützende Elemente | ST = Steel, diameter in [mm] |
Mantelmaterial | low fire hazard |
Mantelfarbe | schwarz |
Norm für flexible Aufzugssteuerleitungen | EN 50214 |
---|