FE5-CL

Safety cable, 0.6/1kV, armoured with rodent protection, euroclass Dca
halogen-free, with improved fire characteristics,
with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5. H

1 Conductor: solid/stranded
2 Insulation: cross-linked PE, zero halogen
3 Inner sheath: Polyolefin, flame retardant, zero halogen
4 Armouring: galvanised steel tape
5 Sheath: FRNC/LSZH

07_Circuit- 04_Propagation 05_Spread 06_Density 08_System- 03_LS0H CPR_Dca CPR_Eca CPR_Fca

Product variants & stock

Article No. Stock ProductReaction to fireDiameter mm²Outer sheath diameter [mm]CU rate [kg/km]Weight [kg/km]Fire load [kWh/m]ConductorConstructionPacking unitGTIN / EAN
19628600DZ
FE5-CL 1 x 35Dca-s2,d1,a135143784880.74strandedLby the metre40393910017991
18838900DZ
FE5-CL-J 5 x 10Dca-s2,d1,a110184807321.56solid3LNPEby the metre40393910035131
19040100DZ
FE5-CL-J 5 x 16Dca-s2,d1,a1162476811202.03stranded3LNPEby the metre40393910032857
18092900DZ
FE5-CL-J 7 x 6Dca-s2,d1,a16174036241.1solid6LPEby the metre40393910042573
18453100DZ
FE5-CL-J 7 x 10Dca-s2,d1,a110206729501.48solid6LPEby the metre40393910040104
19059500DZ
FE5-CL-J 5 x 6Dca-s2,d1,a16162884900.92solid3LNPEby the metre40393910032581
19103600DZ
FE5-CL-J 5 x 50Dca-s2,d1,a15036240031444.74stranded3LNPEby the metre40393910032048
19106300DZ
FE5-CL-J 5 x 25Dca-s2,d1,a12528120017102.76stranded3LNPEby the metre40393910031966
19106400DZ
FE5-CL-J 5 x 2.5Dca-s2,d1,a12.5121202600.59solid3LNPEby the metre40393910031928
19109000DZ
FE5-CL-J 5 x 35Dca-s2,d1,a13531.8168022773.44stranded3LNPEby the metre40393910031836
19156800DZ
FE5-CL-J 3 x 10Dca-s2,d1,a110162884990.91solidLNPEby the metre40393910030358
19160000DZ
FE5-CL-J 5 x 95Dca-s2,d1,a19549456058548.16stranded3LNPEby the metre40393910030266
19273000DZ
FE5-CL-J 3 x 2.5Dca-s2,d1,a12.510721680.41solidLNPEby the metre40393910026887
19273100DZ
FE5-CL-J 5 x 4Dca-s2,d1,a14141923640.73solid3LNPEby the metre40393910026856
19626800DZ
FE5-CL-J 3 x 1.5Dca-s2,d1,a11.59431180.3solidLNPEby the metre40393910018400
19626400DZ
FE5-CL-J 5 x 1.5Dca-s2,d1,a11.510721750.45solid3LNPEby the metre40393910018431
19621600DZ
FE5-CL-J 1 x 300Dca-s2,d1,a130033297633543.61strandedLby the metre40393910018622
19109100DZ
FE5-CL-J 3 x 4Dca-s2,d1,a14111152380.48solidLNPEby the metre40393910031799
19626100DZ
FE5-CL-J 4 x 2.5Dca-s2,d1,a12.511962140.48solid3LPEby the metre40393910018523
19627500DZ
FE5-CL-J 2 x 1.5Dca-s2,d1,a11.58291120.28solidLNby the metre40393910018196
19586400DZ
FE5-CL-J 2 x 2.5Dca-s2,d1,a12.510491510.37solidLNby the metre40393910021110
19167200DZ
FE5-CL-J 4 x 1.5Dca-s2,d1,a11.59581510.36solid3LPEby the metre40393910030013
19164500DZ
FE5-CL-J 3 x 6Dca-s2,d1,a16131733290.65solidLNPEby the metre40393910030167

Technical specifications

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications. The cable should only be laid directly in earth or water if a protective conduit is used. Permitted operating temperature at conductor of +90°C.
Minimum bending radius permanent (multi core) 12 x D
Minimum bending during installation (single core) 15 x D
Minimum bending radius permanent (single core) 15 x D
Minimum bending during installation (multi core) 12 x D
Circuit integrity (FE180) No
System circuit integrity No
Installation temperature -5 °C - +50 °C
Operating temperature -45 °C - +90 °C
Test voltage at 50Hz 3500
Nominal voltage 0.6/1kV
Additional dimensions available on request.
Conductor Bare copper, solid or stranded, IEC 60228, EN 60228
Insulation Cross-linked Polyethylene CENELEC HD 604 S1 part 5 sec. H
Core colours CENELEC HD 308 S2
Inner sheath Flame retardant Polyolefin compound CENELEC HD 604 S1 part 5 sec. H
Armouring (rodent protection) galvanised steel tape (CL)
Outer sheath material Flame retardant Polyolefin compound CENELEC HD 604 S1 part 5 sec. H
Reaction to fire EN 13501-6
Euroclass Dca
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
Flame spread IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2

Documentation