FE5-CL

Safety cable, 0.6/1kV, armoured with rodent protection, euroclass Cca
halogen-free, with improved fire characteristics,
with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5. H

1 Conductor: solid/stranded
2 Insulation: cross-linked PE, zero halogen
3 Inner sheath: Polyolefin, flame retardant, zero halogen
4 Armouring: galvanised steel tape
5 Sheath: FRNC/LSZH

07_Circuit- 04_Propagation 05_Spread 06_Density 08_System- 03_LS0H CPR_Cca CPR_Dca CPR_Eca CPR_Fca

Product variants & stock

Article No. Stock ProductReaction to fireDiameter mm²Outer sheath diameter [mm]CU rate [kg/km]Weight [kg/km]Fire load [kWh/m]ConductorConstructionPacking unitGTIN / EAN
19628600CZ
FE5-CL 1 x 35Cca-s1a,d1,a135143784880.74strandedLby the metre40393910018004
19626100CZ
FE5-CL-J 4 x 2.5Cca-s1a,d1,a12.511962140.48solid3LPEby the metre40393910018530
18838900CZ
FE5-CL-J 5 x 10Cca-s1a,d1,a110184807321.56solid3LNPEby the metre40393910035148
19040100CZ
FE5-CL-J 5 x 16Cca-s1a,d1,a1162476811202.03stranded3LNPEby the metre40393910032864
19109000CZ
FE5-CL-J 5 x 35Cca-s1a,d1,a13531.8168022773.44stranded3LNPEby the metre40393910031843
19626400CZ
FE5-CL-J 5 x 1.5Cca-s1a,d1,a11.510721750.45solid3LNPEby the metre40393910018448
18092900CZ
FE5-CL-J 7 x 6Cca-s1a,d1,a16174036241.1solid6LPEby the metre40393910042580
18453100CZ
FE5-CL-J 7 x 10Cca-s1a,d1,a110206729501.48solid6LPEby the metre40393910040111
19059500CZ
FE5-CL-J 5 x 6Cca-s1a,d1,a16162884900.92solid3LNPEby the metre40393910032598
19103600CZ
FE5-CL-J 5 x 50Cca-s1a,d1,a15036240031444.74stranded3LNPEby the metre40393910032055
19106300CZ
FE5-CL-J 5 x 25Cca-s1a,d1,a12528120017102.76stranded3LNPEby the metre40393910031973
19106400CZ
FE5-CL-J 5 x 2.5Cca-s1a,d1,a12.5121202600.59solid3LNPEby the metre40393910031935
19109100CZ
FE5-CL-J 3 x 4Cca-s1a,d1,a14111152380.48solidLNPEby the metre40393910031805
19156800CZ
FE5-CL-J 3 x 10Cca-s1a,d1,a110162884990.91solidLNPEby the metre40393910030365
19160000CZ
FE5-CL-J 5 x 95Cca-s1a,d1,a19549456058548.16stranded3LNPEby the metre40393910030273
19273000CZ
FE5-CL-J 3 x 2.5Cca-s1a,d1,a12.510721680.41solidLNPEby the metre40393910026894
19273100CZ
FE5-CL-J 5 x 4Cca-s1a,d1,a14141923640.73solid3LNPEby the metre40393910026863
19621600CZ
FE5-CL-O 1 x 300Cca-s1a,d1,a130032.9297633543.61strandedLby the metre40393910018639
19626800CZ
FE5-CL-J 3 x 1.5Cca-s1a,d1,a11.59431180.3solidLNPEby the metre40393910018417
19627500CZ
FE5-CL-O 2 x 1.5Cca-s1a,d1,a11.58291120.28solidLNby the metre40393910018202
19164500CZ
FE5-CL-J 3 x 6Cca-s1a,d1,a16131733290.65solidLNPEby the metre40393910030174
19586400CZ
FE5-CL-O 2 x 2.5Cca-s1a,d1,a12.510491510.37solidLNby the metre40393910021127
19167200CZ
FE5-CL-J 4 x 1.5Cca-s1a,d1,a11.59581510.36solid3LPEby the metre40393910030020

Technical specifications

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications. The cable should only be laid directly in earth or water if a protective conduit is used. Permitted operating temperature at conductor of +90˚C.
Minimum bending radius permanent (multi core) 12 x D
Minimum bending during installation (single core) 15 x D
Minimum bending radius permanent (single core) 15 x D
Minimum bending during installation (multi core) 12 x D
Circuit integrity (FE180) No
System circuit integrity No
Installation temperature -5 °C - +50 °C
Operating temperature -45 °C - +90 °C
Conductor Bare copper, solid or stranded in accordance with IEC 60228 and EN 60228
Insulation Cross-linked Polyethylene CENELEC HD 604 S1 part 5 sec. H
Core colours CENELEC HD 308 S2
Armouring (rodent protection) Single-core cable with copper tape (CLCU) and multicore cable with galvanised steel tape (CL)
Outer sheath material Flame retardant Polyolefin compound CENELEC HD 604 S1 part 5 sec. H
Reaction to fire EN 13501-6
Euroclass Cca
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
Flame spread IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2

Documentation