N2XCH

Safety cable, 0.6/1kV, Euroclass Cca
halogen-free, with improved fire characteristics,
CENELEC HD 604 S1, VDE 0276-604

1 Conductor: solid/ stranded
2 Insulation: cross-linked PE, zero halogen
3 Filler: flame retardant, zero halogen
4 Concentric conductor: bare copper wire
5 Reinforcing helix: bare copper tape
6 Separator: plastic tape
7 Sheath: FRNC/LSZH

07_Circuit- 04_Propagation 05_Spread 06_Density 08_System- 03_LS0H CPR_Cca CPR_Dca CPR_Eca

Product variants & stock

Article No. Stock ProductReaction to fireDiameter mm²Outer sheath diameter [mm]CU rate [kg/km]Weight [kg/km]Fire load [kWh/m]ConductorConstructionPacking unitGTIN / EAN
17017204CZ
N2XCH 3 x 50/25Cca-s1,d1,a150/2529172319902.72solid3Lby the metre40393910100082
17017404CZ
N2XCH 3 x 120/70Cca-s1,d1,a1120/7041.6423652705.55stranded3Lby the metre40393910100051
17017504CZ
N2XCH 3 x 70/35Cca-s1,d1,a170/3534.8241028304.11stranded3Lby the metre40393910100037
17018404CZ
N2XCH 4 x 50/25Cca-s1,d1,a150/2534.4220326003.38stranded3LNby the metre40393910099966
17018504CZ
N2XCH 4 x 70/35Cca-s1,d1,a170/3540.5308235504.48stranded3LNby the metre40393910099942
17018604CZ
N2XCH 4 x 95/50Cca-s1,d1,a195/5044.4420848005.44stranded3LNby the metre40393910099911
17018704CZ
N2XCH 4 x 120/70Cca-s1,d1,a1120/7048.3538265006.38stranded3LNby the metre40393910099898
17018804CZ
N2XCH 4 x 150/70Cca-s1,d1,a1150/7053.2654079507.97stranded3LNby the metre40393910099874
17018904CZ
N2XCH 4 x 185/95Cca-s1,d1,a1185/9558.9815999709.86stranded3LNby the metre40393910099843
17019704CZ
N2XCH 3 x 95/50Cca-s1,d1,a195/5037.7329643504.60stranded3Lby the metre40393910099805
17019804CZ
N2XCH 3 x 150/70Cca-s1,d1,a1150/7045.6510054506.68stranded3Lby the metre40393910099782

Technical specifications

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications. The cable should only be laid directly in earth or water if a protective conduit is used. Permitted operating temperature at conductor of +90˚C.
Minimum bending radius permanent (multi core) 12 x D
Minimum bending during installation (multi core) 12 x D
Remarks bending radius *50% reduction if installation at 30°C and with a template
Circuit integrity (FE180) No
System circuit integrity No
Installation temperature -5 °C - +50 °C
Operating temperature -45 °C - +90 °C
Imprint Sur demande
Conductor Bare copper, solid or stranded, IEC 60228 and EN 60228 (VDE 0295)
Insulation Cross-linked Polyethylene, CENELEC HD 604 S1 and VDE 0276-604
Core colours CENELEC HD 308 S2, VDE 0293
Filler Halogen-free compound or plastic tape
Concentric conductor Bare copper wires with reinforced helix
Outer sheath material Flame retardant Polyolefin compound, CENELEC HD 604 S1 and VDE 0276-604 "HM4"
Reaction to fire EN 13501-6
Euroclass Cca
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
Flame spread IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2

Documentation