Datwyler Data-R LSOH

Round data bus cable FR/LSOH, Euroclass Dca

1 Conductor: solid
2 Shielding: Alu-laminated plastic foil with drain wire
3 Sheath: FRNC/LS0H

04_Propagation 05_Spread 06_Density 03_LS0H

Product variants & stock

Article No. Stock ProductReaction to fireOuter sheath materialOuter sheath diameter [mm]CU rate [kg/km]Weight [kg/km]Fire load [kWh/m]Packing unitGTIN / EAN
18106302DK
Data-R 1 x 2Dca-s2,d2,a1FR/LSZH615440.121000 m drum40393910099607
18106402DK
Data-R 2x2Dca-s2,d2,a1FR/LSZH725600.161000 m drum40393910099553

Technical specifications

Special bus cable for the decentralised Datwyler EIB system for installation in dry rooms with medium mechanical requirements. The cable can also be used in areas with explosion risk and run through damp and wet rooms. This cable type is not suitable for outdoor applications. Max. permitted temperature at conductor is 70°C.De kabel kan ook worden gebruikt in zones met explosiegevaar en kan lopen door vochtige en natte ruimtes.Dit type kabel is niet geschikt voor buitentoepassingen.Max. toegestane temperatuur aan de geleider is 70 ° C.
Test voltage at 50Hz 4000
peak voltage 300
System circuit integrity No
Installation temperature - +50 °C
Operating temperature +70 °C
Reaction to fire EN 13501-6
Euroclass Dca
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Flame spread IEC 60332-3-25, EN 60332-3-25, VDE 0482-332-3

Documentation