DCS trunk cable, LCDU/PC - LCDU/PC, E9/125 G.652.D BLO

for interconnecting DCS breakout modules

DCS trunk cable, 6x LCDU/PC, G.652.D BLO

Product variants & stock

Article No. Stock ProductOuter sheath colourNumber of fibresFibre typeOuter sheath materialOuter sheath diameter [mm]PolarityNumber of connectors side ANumber of connectors side BNumber of fibres per connector ANumber of fibres per connector BGradationPacking unitGTIN / EAN
47406100ZY
DCS trunk cable 6x LCDU/PC - 6x LCDU/PCyellow12E9/125 G.652.D BLOFR/LSZH5.9A to A6622graduated lengthby the metre40393910006704
47406300ZY
DCS trunk cable 12x LCDU/PC - 12x LCDU/PCyellow24E9/125 G.652.D BLOFR/LSZH9.9A to A121222graduated lengthby the metre40393910006681
47406500ZY
DCS trunk cable 24x LCDU/PC - 24x LCDU/PCyellow48E9/125 G.652.D BLOFR/LSZH9.9A to A242422graduated lengthby the metre40393910006667
47406700ZY
DCS trunk cable 48x LCDU/PC - 48x LCDU/PCyellow96E9/125 G.652.D BLOFR/LSZH12.9A to A484822graduated lengthby the metre40393910209198
47409100ZY
DCS trunk cable 6x LCDU/PC - 6x LCDU/PCyellow12E9/125 G.652.D BLOFR/LSZH5.9A to B6622graduated lengthby the metre40393910006643
47409300ZY
DCS trunk cable 12x LCDU/PC - 12x LCDU/PCyellow24E9/125 G.652.D BLOFR/LSZH9.9A to B121222graduated lengthby the metre40393910006629
47409500ZY
DCS trunk cable 24x LCDU/PC - 24x LCDU/PCyellow48E9/125 G.652.D BLOFR/LSZH9.9A to B242422graduated lengthby the metre40393910006605
47409700ZY
DCS trunk cable 48x LCDU/PC - 48x LCDU/PCyellow96E9/125 G.652.D BLOFR/LSZH12.9A to B484822graduated lengthby the metre40393910209174

Technical specifications

Compact, metal-free cable construction with FR/LS0H cable sheath and 12 to 96 fibres. Sticker labelling at both cable ends. The length of individual cables (&quot;legs&quot;) may be defined on the basis of a specific project (standard 0.75 m). The leg separation is effected with a divider housing. All individual cables are assembled using LCDU Intelli-Cross<sup>®</sup> Pro. Standard polarities are A to A or A to B. The cables are fitted at both ends with protective sleeves.
Cable raw material FO Indoor ZGGFR/SZGGFR / J-B(ZN)BH, B2ca
OS2 LCDU-on-LCDU trunk cables are suitable for all high-performance applications with duplex and parallel optic signals in a data centre environment.
They are particularly used when installation requires sturdy, metal-free indoor cables that provide enhanced crush resistance and rodent protection.
For duplex applications, the pre-assempled connectors at either end of the cable are connected to the DCS modules.
The DCS trunk cables are assembled to a very high quality and guarantee optimum values for optical performance (IL/RL).
Housing colour connector A blue
Housing colour connector B blue
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Flame spread IEC 60332-3-24
Outer sheath material FR/LSZH
Outer sheath colour yellow
Fibre type E9/125 G.652.D BLO
Colour code IEC 60304
Connector type side A LCDU/PC
Ferrule polishing connector A PC 0°
IL maximal, connector A 0.25 dB
IL typical, connector A 0.12 dB
RL minimal, connector A 50 dB
RL typical, connector A 55 dB
Connector type side B LCDU/PC
Ferrule polishing connector B PC 0°
IL maximal, connector B 0.25 dB
IL typical, connector B 0.12 dB
RL minimal, connector B 50 dB
RL typical, connector B 55 dB

Documentation