FO Outdoor wbKT Micro Combi / A-DQS(ZN)2Y

Micro Combi, up to 48 fibres + 2 stranded copper wires, Euroclass Fca
dry interstices

1 Copper wire, stranded, 0.50 mm2
2 Loose tube with ≤ 12 fibres
3 Support element
4 Loose tube
5 Swelling tape
6 Aramid yarn / ripcord
7 PE sheath

04_Propagation- 05_Spread- 06_Density- 08_System- 03_LS0H CPR_Fca

Product variants & stock

Article No. Stock Loose tube constructionFibres per loose tubeNumber of used loose tubesProductReaction to fireOuter sheath colourNumber of fibresFibre typeFibre categoryOuter sheath diameter [mm]Bending radius [mm]CU rate [kg/km]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Packing unitGTIN / EAN
19440900FZ
6124wbKT Micro Combi 4x12 + 2x0.50Fcablack48E9/125 G.652.D BLOOS26.51501045100016006000.25by the metre40393910022148

Technical specifications

Very compact fibre optic outdoor cable with up to 48 fibres in stranded loose tubes, dry interstices and two stranded copper wires. Easily cut-back, installation friendly cable construction. The two coloured ripcords are easy to identify and enable the safe opening of the cable sheath.
Maximum number of fibres 72
Field of application Outdoor
Installation temperature -10 °C - +40 °C
Storage temperature -25 °C - +70 °C
Operating temperature -25 °C - +70 °C
Imprint DATWYLER «cable type» «additional text» «batch number» «meter marks»
For injection into microducts,
particularly for safety-related applications such as
- power supply of remote systems
- remote control of connecting technology
Datwyler recommends blowing in micro and mini cables in an ambient temperature range from -2°C to +35°C.
For installation, a blow-in device with a rubber pull-in bead is recommended.

This cable meets the requirements of the Catalogue of Safety Requirements for Operating Telecommunication and Data Processing Systems as well as for Processing Personal Data in Accordance with § 109 German Telecommunications Act (TKG)"" of the German Bundesnetzagentur.""
Tensile performance IEC 60794-1-21 E1
Crush resistance IEC 60794-1-21 E3
Impact IEC 60794-1-21 E4
Repeated bending IEC 60794-1-21 E6
Torsion IEC 60794-1-21 E7
Kink IEC 60794-1-21 E10
Bend IEC 60794-1-21 E11
Temperature cycling IEC 60794-1-22 F1
Water penetration IEC 60794-1-22 F5
Reaction to fire EN 13501-6
Euroclass Fca
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Armouring (rodent protection) non-armoured
Outer sheath material HDPE