Back to: Outdoor cable

FO Outdoor wbGGT HP City / A-DQ(ZN)B2Y

HighP, 2-layer Euroclass Fca
metal-free, dry interstices,
longitudinally watertight, rodent protection

1 ≤ 24 fibres
2 Swelling tape
3 Loose tube
4 Glass armour
5 Ripcord
6 HDPE sheath

Description

Compact fibre optic outdoor cable with up to 576 fibres for city and access networks.
2-layer loose tube construction, longitudinally water protected and with dry strand interstices.
The glass armour provides for a combined non-metallic rodent protection and strain relief.
The two coloured ripcords are easy to identify and enable the safe opening of the cable sheath.
HDPE cable sheath, easy to lay.
Direct burial.

  • Optimised for blowing into compact thermoplastic ducts.
  • Outer sheath material HDPE
  • Armouring (rodent protection) rodent protected
  • Installation temperature -10 °C - +50 °C
  • Storage temperature -40 °C - +70 °C
  • Operating temperature -40 °C - +70 °C
  • Field of application Outdoor
  • Imprint DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
  • Tensile performance IEC 60794-1-21 E1
  • Crush resistance IEC 60794-1-21 E3
  • Impact IEC 60794-1-21 E6
  • Repeated bending IEC 60794-1-21 E7
  • Torsion IEC 60794-1-21 E11
  • Bend IEC 60794-1-22 F5
  • Reaction to fire (Euroclasses) EN 13501-6: Fca
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2

Documentation

ENDENLFRCNESIT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet file-icon
GHMT PVP Certificates GHMT PVP Certificates GHMT PVP Certificates file-icon file-icon file-icon file-icon file-icon
Tender text file-icon file-icon Tender text file-icon file-icon file-icon file-icon

Versions

Article No.StockProductReaction To FireOuter sheath colourNumber of FibresFibre typeOuter sheath diameter [mm]Bending radius [mm]Weight [kg\km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh\m]Packing unitFibre categoryFibres per loose tubeLoose tube constructionNumber of used loose tubes
19070900FZ FO Outdoor HP City 15x12Fcablack180E9/125 G.652.D OS218.9 mm470 mm2689000500030002.492 kWh/mby the metreOS2121815
19069900FZ FO Outdoor HP City 16x12Fcablack192E9/125 G.652.D OS218.9 mm470 mm2689000500030002.492 kWh/mby the metreOS2121816
19017600FZ FO Outdoor HP City 18x12Fcablack216E9/125 G.652.D OS218.9 mm470 mm2689000500030002.492 kWh/mby the metreOS2121818
19169300FZ FO Outdoor HP City 20x12Fcablack240E9/125 G.652.D OS222 mm550 mm3339000500030002.568 kWh/mby the metreOS2122420
19017800FZ FO Outdoor HP City 18x24Fcablack432E9/125 G.652.D OS220.2 mm515 mm3369000500030003.115 kWh/mby the metreOS2241818
19720400FZ FO Outdoor HP City 24x24Fcablack576E9/125 G.652.D OS219.6 mm300 mm3109000500030002.346 kWh/mby the metreOS2242424