CU SPE 1P

Data cable, S/FTP, AWG22, Euroclass Dca
600 MHz

1 Inner conductor: AWG22
2 PE insulated conductor: Ø 1.6 mm
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: FRNC/LSZH

CPR_Eca 05_Spread- 04_Propagation 03_LS0H CPR_Dca 06_Density 02_PoEp_rt 01_RoHS 09_Oil- 08_System- 10_Schielded_EN

Product variants & stock

Article No. Stock ProductReaction to fireDimensions n x p x [mm (AWG)]Outer sheath colourOuter sheath dimensions [mm]CU rate [kg/km]Weight [kg]Packing unitGTIN / EAN
19143100DK
CU SPE 1P AWG 22Dca–s2,d1,a11 x 2 x 0.62 (AWG22)grey4.611.90.03 kg1000 m drum40393910031072

Technical specifications

Electrically and mechanically high-quality 1-pair cable for Single Pair Ethernet (SPE) application and for frequencies up to 600 MHz. Complies and exceeds the requirements of ISO/IEC 11801-1 Amd 1 “General Requirements”, ISO/IEC 11801-3 Amd 1 “Industrial Premises”, ISO/IEC 11801-6 Amd 1 “Distributed Building Services”, TR 11801-9906 “one pair channel” and IEC 61156-11 “Symmetrical single pair cables with transmission characteristics up to 600 MHz”. Excellent shielding effectiveness due to individually screened pair and overall copper braid. Compatible with all current Single Pair Ethernet connecting hardware in accordance with IEC 63171 series.
Category Single pair Ethernet
Loop resistance at 20 °C 120 Ω/km
Operating capacity 43 pF/m
Impedance at 100 MHz, ±5Ω 100 Ω
NVP % 78
Coupling attenuation 85 dB
Segregation class d
Shielding shielded
AWG 22
Minimum bending radius permanently installed 22 mm
Maximum tensile strength 25 N
Solid / Flex Solid wire
Field of application Single pair Ethernet
Wire colour white/blue
Installation temperature 0 °C - +50 °C
Operating temperature -20 °C - +70 °C
Imprint DATWYLER «cable type» «additional text» «batch number» «meter marks»
Data cable - suitable for use as a laying and installation cable in a single-pair Ethernet environment.
For the transmission of digital and analogue data, voice and video signals.
Suitable for IP based 2-wire bus applications with conductor wire size of AWG 22.
Applicable for Power over Data Line (PoDL) and for 1-pair PoE.
Reaction to fire EN 13501-6
Euroclass Dca
Smoke density IEC 61034-1/-2, EN 61034-1/-2
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2
Flame propagation IEC 60332-1-2, EN 60332-1-2
Cables standard ISO/IEC 61156-11
Cat./Class Single pair Ethernet SPE and IEC 61156-11 guaranteed
PoDL (PoE) IEEE 802.3bu
Outer sheath material FRNC/LSZH

Documentation