CU 8206 4P flex

Flexible data cable, S/FTP, Category 8.2, AWG26, Euroclass Dca
2000 MHz

1 Inner conductor: AWG26, bare copper wire, stranded
2 PE insulated conductor: Ø 0.99 mm
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: FRNC/LS0H grey, RAL 7035

01_RoHS 04_Propagation 05_Spread- 09_Oil- 02_PoEp_rt 10_Schielded_EN 06_Density 08_System- 03_LS0H CPR_Dca CPR_Eca

Product variants & stock

Article No. Stock ProductReaction to fireDimensions n x p x [mm² (AWG)]Outer sheath dimensions [mm]CU rate [kg/km]Weight [kg/km]Fire load [kWh/m]Packing unitGTIN / EAN
19206800DK
CU 8206 4P FlexDca-s2,d1,a14 x 2 x 0.132 (AWG26)5.818.1370.111000 m drum40393910028003

Technical specifications

Electrically and mechanically superior quality Cat.8.2 patch cord - exceeds the requirements of ISO/IEC 11801, IEC 61156-6, EN 50173-1, EN 50288-4-2 and IEC 61156-10. Excellent shielding effect due to individually screened pairs and overall copper braid. Compact cable design. Easy wire identification and termination due to different coloured wires. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
AWG 26
Repeated bending 1000 cycles
Tensile strength (4P) 56 N
Minimum number of impacts 10
Solid / Flex Stranded wire (flexible)
Minimum bending radius 20 mm
Category Cat.8.2
Loop resistance at 20 °C 270 Ω/km
Operating capacity 43 pF/m
Transfer impedance 10 mΩ/m
Delay skew 4 ns/100 m
Impedance at 100 MHz, ±5Ω 100 Ω
Transfer impedance 1/10/30 MHz 10 mΩ/m
Near end unbalance attenuation LCL at 1-600 MHz 40 dB
NVP % 78
Coupling attenuation 85 dB
GBit/s Up to 40 Gbit/s
Shielding shielded
Patch cord in patch panels and as equipment connection cable.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to 2000 MHz.
Applicable for Power over Ethernet (PoE / PoE+).
Wire colour white/blue-white, white/orange-white, white/green-white, white/brown-white (with length stripes)
Field of application Indoor
Installation temperature 0 °C - +50 °C
Operating temperature -20 °C - +60 °C
Imprint DATWYLER «cable type» «additional text» «batch number» «meter marks»
Reaction to fire EN 13501-6
Euroclass Dca
Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Cables standard ISO/IEC 61156-10, EN 50288-12-2
Cat./Class Cat.8.2 / Class I/II
PoE IEEE 802.3af
Outer sheath material FRNC/LSZH
Outer sheath colour grey

Documentation